Contact us, we will be pleased to advise you.

Europe's most comprehensive online shop for power generators

ITC Power  |  SKU: SEV-00601

ITC POWER DG7800LE-T diesel generator

Normal price DA 201,000.00
Shipping will be calculated at checkout.

ITC POWER DG7800LE-T diesel generator is not in stock and will be shipped as soon as available again.

Delivery time: approx. 10 days


Collection possible from warehouse Fabrikstr. 1

Collection date after consultation

Questions to the product?

Shipping Information

Shipping costs are calculated based on the weight and the destination country. A shipping cost calculator for the entire contents of the shopping cart is available here on the product page (below the price information).

We ship up to approx. 30 kg with parcel service. We ship items with higher weight using general cargo freight forwarding or, in the case of large units, by direct transport.

Please contact us if you have special delivery requirements.

ITC POWER · DIESEL GENERATOR

ITC POWER DG7800LE-T Diesel Stromaggregat

The ITC POWER DG7800LE-T is an open-frame diesel generator with 230 V and 400 V outputs, AVR voltage regulation, and electric/recoil starting. The configuration currently recorded by SEV specifies 7.5 kVA rated and 7.9 kVA maximum output at 400 V. Its air-cooled D500E engine runs at 3,000 rpm. Manufacturer specifications for the tank and 230 V output vary by version.

Key specifications

Maximum output
7,9 kVA / 400 V
Rated output
7,5 kVA / 400 V
Voltage
230 / 400 V
Fuel
Diesel
Tank capacity
10 l (ältere Datenlage)
Net weight
116 kg

Open-frame 230/400 V diesel generator

The three-phase DG7800LE-T diesel generator can power compatible single- and three-phase loads on construction sites, in field service and temporary applications. Rated 400 V output is 7.5 kVA. For single-phase loads, the socket current limit and usable phase power must also be respected.

The 498 cc D500E diesel engine can be started electrically or by recoil. AVR stabilizes output voltage and an LED6 digital display assists monitoring. The open-frame construction improves access for routine checks, but requires suitable siting for exhaust and noise.

Important version note: Older DG7800LE-T documentation specifies a 10-litre tank and 5.4 kW rated output at 230 V. Newer catalogues for model designation DG7800LET specify a 14-litre tank and higher 230 V ratings. These datasets should not be mixed without confirming the actual supplied version.

Benefits and equipment

✓ 230 V and 400 V

CEE outputs for compatible single- and three-phase equipment.

✓ Electric and recoil start

Flexible starting for the 498 cc diesel engine.

✓ AVR voltage regulation

Automatic voltage stabilization as loads change.

✓ Open frame

Accessible engine and alternator components.

Typical applications

Trades and installation

230/400 V tools with suitable load requirements.

Construction sites

Temporary diesel power for compatible equipment.

Agriculture and field service

Off-grid supply with proper safe positioning.

Technical specifications

Engine
Engine modelD500E
DesignAir-cooled four-stroke single-cylinder diesel
Displacement498 cm³
Engine speed3.000 U/min
FuelDiesel
Alternator / inverter
AlternatorAL6-T (ältere Version)
Voltage regulationAVR
Phases3
Rated voltage230 / 400 V
Frequency50 Hz
Output ratings
Maximum output7,9 kVA / 400 V
Rated output7,5 kVA / 400 V
Important sizing noteCheck starting current, phase load and outlet ratings
Fuel / operation
Tank capacity10 l (ältere Datenlage)
Oil capacity1,75 l (ältere Version)
RuntimeStore information approx. 6 h at 75% load; check configuration
Starting systemElectric and recoil start
Connections
AC outlets1 × CEE 400 V / 16 A; 1 × CEE 230 V / 32 A
Load sizingObserve each outlet limit and motor starting current
Dimensions / weight
Dimensions (L × W × H)720 × 480 × 600 mm
Net weight116 kg
Sound pressure at 7 m79 dB(A) (ältere Variante)
Additional technical details
Technical notesThe SEV store configuration matches older ITC documents for power, tank and noise. The 2024/2025 DG7800LET catalogue lists different 230 V output figures, a 14-litre tank and 77 dB(A). Verify the exact version and nameplate before ordering.
Data validationSpecifications refer to the documented product configuration; verify before final system design

Frequently asked questions about DG7800LE-T

What is the 400 V output?

The version currently listed in the store is rated at 7.5 kVA, with 7.9 kVA maximum output.

Why do fuel-tank specifications differ?

Older ITC documents specify 10 litres, while newer DG7800LET catalogues say 14 litres. The supplied configuration must be confirmed.

Can I use 230 V and 400 V at the same time?

Available load distribution depends on the exact generator version and maximum phase current. Output ratings cannot be added together.

Is this suitable for sensitive devices?

AVR regulates voltage. Very sensitive equipment requires a separate power-quality compatibility check.

Can it be connected directly to house wiring?

No. Building backup requires professional isolation, changeover and electrical protection.

Compare related ITC POWER generators

The sound-enclosed ITC POWER 8000D-T is an alternative with similar 400 V rated output. For exclusively single-phase 230 V loads, the DG7800LE may be more suitable.

ITC POWER 8000D-T →

Need help choosing a generator?

SEV can help you size the generator, check its outlets and design suitable professional backup power connections.

Contact SEV +49 7622 6971 150

Payment & Security

Payment methods:

  • American Express
  • Apple Pay
  • Bancontact
  • BLIK
  • EPS
  • Google Pay
  • iDEAL Wero
  • Maestro
  • Mastercard
  • MobilePay
  • PayPal
  • Shop Pay
  • Twint
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store any credit card details and do not have access to your credit card details.